PHONE : 982144972925-7+

RE-Y(ST)YRY MultiTriple

(RE-Y(St)YRY Multi Triple (0.5-2.5
Code No. of cores External diameter Armour wire diameter Cable weight Packing*
.No
    N x mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :0.5
3615 1 11.3 0.9 250 CUT
3625 2 14.8 0.9 375 CUT
3635 3 15.5 0.9 415 CUT
3645 4 16.5 0.9 475 CUT
3655 5 17.8 0.9 535 CUT
3665 6 19 0.9 595 CUT
3675 7 19 0.9 625 CUT
36105 10 23.8 1.25 960 CUT
36125 12 24.4 1.25 1040 CUT
36165 16 26.7 1.25 1230 CUT
36205 20 29.9 1.6 1610 CUT
36245 24 32.7 1.6 1840 CUT
36305 30 34.3 1.6 2070 CUT
Cross Section :0.75
3617 1 11.8 0.9 275 CUT
3627 2 15.6 0.9 415 CUT
3637 3 16.2 0.9 470 CUT
3647 4 17.5 0.9 545 CUT
3657 5 18.7 0.9 615 CUT
3667 6 20.1 0.9 685 CUT
3677 7 20.1 0.9 720 CUT
36107 10 25.4 1.25 1110 CUT
36127 12 26 1.25 1210 CUT
36167 16 29.3 1.6 1625 CUT
36207 20 32.2 1.6 1895 CUT
36247 24 36.1 2 2430 CUT
36307 30 37.9 2 2725 CUT
Cross Section :1.0
36110 1 12.2 0.9 290 CUT
36210 2 16.3 0.9 450 CUT
36310 3 17 0.9 510 CUT
36410 4 18.4 0.9 600 CUT
36510 5 19.6 0.9 685 CUT
36610 6 22 1.25 900 CUT
36710 7 22 1.25 945 CUT
361010 10 26.9 1.25 1255 CUT
361210 12 28.3 1.6 1545 CUT
361610 16 30.9 1.6 1820 CUT
362010 20 34 1.6 2145 CUT
362410 24 38.1 2 2725 CUT
363010 30 40 2 3095 CUT
           
Code No. of cores External diameter Armour wire diameter Cable weight Packing*
.No
    N x mm² approx. nominal approx.  
  mm mm kg/km  
Cross Section :1.5
36115 1 13 0.9 335 CUT
36215 2 17.6 0.9 530 CUT
36315 3 18.4 0.9 610 CUT
36415 4 19.8 0.9 710 CUT
36515 5 22.2 1.25 960 CUT
36615 6 23.7 1.25 1065 CUT
36715 7 23.7 1.25 1130 CUT
361015 10 29.8 1.6 1705 CUT
361215 12 30.9 1.6 1870 CUT
361615 16 33.7 1.6 2235 CUT
362015 20 38 2 2905 CUT
362415 24 42.1 2 3405 CUT
363015 30 45.4 2.5 4330  
Cross Section :2.5
36125 1 14.4 0.9 410 CUT
36225 2 19.9 0.9 660 CUT
36325 3 21.8 1.25 925 CUT
36425 4 23.5 1.25 1085 CUT
36525 5 25.3 1.25 1240 CUT
36625 6 27.4 1.25 1410 CUT
36725 7 27.4 1.25 1510 CUT
361025 10 35.7 2 2525 CUT
361225 12 36.7 2 2755 CUT
361625 16 40.7 2 3395 CUT
362025 20 45.9 2.5 4410 CUT
362425 24 50.4 2.5 5080 CUT
363025 30 54.5 3.15 6510 CUT
Technical data
Flame Temperature Range MUTUAL CAPACITY (Max) Insulation  Thickness (Nom) Insulation  Resistance (Min) Conductor Resistance class2(Max)
  Propagation
IEC 60332-3-24 -30ºC~+70ºC (FIXED LAYING) pF/m mm2   mm MΩxKm Ω/km mm2
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24 250 0.5 0.6 100 36 0.5
0.75 0.6 24.5 0.75
1 0.6 18.1 1
1.5 0.6 9 1.5
2.5 0.7 12.1 2.5
    7.41  
 
Bending Radius Test Voltage Operating Voltage Current L/R(Ratio) (Max)
Load(25ºC)
7, 5 X Cable Ø C r. /C r. =2 0 0 0 V 300/500V A mm2 µH /Ω mm2
Cr./Scrn.=2000 V 6 0.5 25 0.5
13 0.75 25 0.75
16 1 25 1
20 1.5 40 1.5
25 2.5 60 2.5
Temperature Range               Fixed -40 °C to+70 °C ; During Installation -5 °C -+50 °C
Flame Test                                  IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2)
Design Standards
IEC 60092-376
EN 50288-7
DIN VDE 819-7
Conductor   Annealed Copper or Tinned Copper - Class 2 Acc to IEC 60228 / HD 383 / DIN VDE 0295
Insulation PVC acc to EN 50290-2
Insulation Color Code Pair : white, Black (numbered)
Triple :White, Black , Red (Numbered)
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2 PVC Compound
Armour Galvanized Round Steel Wire
Sheathing PVC compound Type YM1 UV Resistant and Flame retardant Acc to EN 0290-2
Color Black, Red, Blue Or by resuest



 

cable with protective screen against electromagnetic impacts, for reliable and quick (up to 200 kB/s) transmission of analogue and digital signals, suitable for fixed and mobile installations in process control and data processing systems, mostly in chemical and petrochemical industrial plants and electric power plants. Low values of signal attenuation and low mutual capacitance enable large-distance signal transmission. Laid in dry and damp premises, also outdoor, in air or ground. Not intended for supply purposes