RE-Y(ST)Y TIMF

(RE-Y(St)Y TIMF (0.5-2.5
Code No. of cores External diameter Insulation thickness Cable weight Packing*
.No
    N x mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :0.5
3815 1 7.1 0.6 65 CUT
3825 2 11.6 0.6 125 CUT
3835 3 12.3 0.6 160 CUT
3845 4 13.7 0.6 205 CUT
3855 5 15 0.6 250 CUT
3865 6 16.6 0.6 295 CUT
3875 7 16.6 0.6 330 CUT
38105 10 21.4 0.6 465 CUT
38125 12 22.1 0.6 540 CUT
38165 16 24.8 0.6 700 CUT
38205 20 27.9 0.6 870 CUT
38245 24 31.2 0.6 1040 CUT
38305 30 33.3 0.6 1275 CUT
Cross Section :0.75
3817 1 7.5 0.6 75 CUT
3827 2 12.4 0.6 145 CUT
3837 3 13.4 0.6 200 CUT
3847 4 14.7 0.6 250 CUT
3857 5 16.4 0.6 310 CUT
3867 6 17.9 0.6 360 CUT
3877 7 17.9 0.6 405 CUT
38107 10 23.2 0.6 580 CUT
38127 12 24.1 0.6 675 CUT
38167 16 27 0.6 880 CUT
38207 20 30.4 0.6 1090 CUT
38247 24 33.9 0.6 1305 CUT
38307 30 36.2 0.6 1600 CUT
Cross Section :1.0
38110 1 7.9 0.6 90 CUT
38210 2 13.4 0.6 175 CUT
38310 3 14.2 0.6 230 CUT
38410 4 15.6 0.6 290 CUT
38510 5 17.3 0.6 360 CUT
38610 6 19 0.6 420 CUT
38710 7 19 0.6 475 CUT
381010 10 24.7 0.6 680 CUT
381210 12 25.6 0.6 795 CUT
381610 16 28.7 0.6 1040 CUT
382010 20 32.3 0.6 1290 CUT
382410 24 36.3 0.6 1550 CUT
383010 30 38.5 0.6 1890 CUT
           
Code No. of cores External diameter Insulation thickness Cable weight Packing*
.No
    N x mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :1.5
38115 1 8.6 0.6 110 CUT
38215 2 14.6 0.6 215 CUT
38315 3 15.5 0.6 295 CUT
38415 4 17.3 0.6 380 CUT
38515 5 19 0.6 460 CUT
38615 6 21 0.6 550 CUT
38715 7 21 0.6 620 CUT
381015 10 27.4 0.6 895 CUT
381215 12 28.3 0.6 1045 CUT
381615 16 31.8 0.6 1365 CUT
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length

Cable with protective screen against electromagnetic impacts, for reliable and quick (up to 200 kB/s) transmission of analogue and digital signals, suitable for fixed and mobile installations in process control and data processing systems, mostly in chemical and petrochemical industrial plants and electric power plants. Low values of signal attenuation and low mutual capacitance enable large-distance signal transmission. Laid in dry and damp premises, also outdoor, in air or ground. Not intended for supply purposes

 

Conductor   Annealed Copper or Tinned Copper - Class 2 Acc to IEC 60228 / HD 383 / DIN VDE 0295
Insulation PVC acc to EN 50290-2
Insulation Color Code Pair : white, Black (numbered)
Triple :White, Black , Red (Numbered)
Ind. Screen  PES Tape +TINNED COPPER DRAIN WIRE; AL-PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Sheathing PVC compound Type YM1 UV Resistant and Flame retardant Acc to EN 0290-2
Color Black, Red, Blue Or by resuest
Technical data
Flame Temperature Range (MUTUAL CAPACITY (Max Insulation  Thickness )(Nom) Insulation  Resistance (Min) Conductor Resistance class2(Max)
  Propagation
IEC 60332-3-24 -30ºC~+70ºC (FIXED LAYING) pF/m mm2   mm MΩxKm Ω/km mm2
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24 250 0.5 0.6 100 36 0.5
0.75 0.6 24.5 0.75
1 0.6 18.1 1
1.5 0.6 12.1 1.5
2.5 0.7 7.41 2.5
 
Bending Radius Test Voltage Operating Voltage Current L/R(Ratio) (Max)
Load(25ºC)
7, 5 X Cable Ø C r. /C r. =2 0 0 0 V 300/500V A mm2 µH /Ω mm2
Cr./Scrn.=2000 V 6 0.5 25 0.5
13 0.75 25 0.75
16 1 25 1
20 1.5 40 1.5
25 2.5 60 2.5
Temperature Range               Fixed -40 °C to+70 °C ; During Installation -5 °C -+50 °C
Flame Test                                  IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2)
Design Standards
IEC 60092-376
EN 50288-7
DIN VDE 819-7