PHONE : 982144972925-7+

RE-2X(St)YRY Multipair

(RE-2X(St)YRY  Multi pair (0.5-2.5
Code No. of Pairs External diameter Wire armor diameter Cable weight Packing*
No.
    Nx mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :0.5
7315 1 11.9 0.9 255 CUT
7325 2 15.5 0.9 370 CUT
7335 3 16.1 0.9 410 CUT
7345 4 17.2 0.9 460 CUT
7355 5 18.6 0.9 520 CUT
7365 6 19.9 0.9 570 CUT
7375 7 19.9 0.9 590 CUT
73105 10 25 1.25 920 CUT
73125 12 25.7 1.25 980 CUT
73165 16 28.9 1.6 1325 CUT
73205 20 31.5 1.6 1515 CUT
73245 24 34.6 1.6 1715 CUT
73305 30 37.1 2 2155 CUT
Cross Section :0.75
7317 1 12.3 0.9 280 CUT
7327 2 16.1 0.9 400 CUT
7337 3 16.9 0.9 450 CUT
7347 4 18.3 0.9 512 CUT
7357 5 19.5 0.9 570 CUT
7357 6 21.6 1.25 765 CUT
7377 7 21.6 1.25 790 CUT
73107 10 26.4 1.25 1035 CUT
73127 12 27.1 1.25 1105 CUT
73167 16 30.5 1.6 1490 CUT
73207 20 33.6 1.6 1715 CUT
73247 24 37.6 2 2230 CUT
73307 30 39.5 2 2480 CUT
Cross Section :1.0
73110 1 12.7 0.9 290 CUT
73210 2 16.7 0.9 425 CUT
73310 3 17.5 0.9 481 CUT
73410 4 19 0.9 555 CUT
73510 5 20.3 0.9 625 CUT
73610 6 22.5 1.25 830 CUT
73710 7 22.5 1.25 860 CUT
731010 10 28.5 1.6 1310 CUT
731210 12 29.3 1.6 1415 CUT
731610 16 31.9 1.6 1630 CUT
732010 20 35.9 2 2160 CUT
732410 24 39.4 2 2445 CUT
733010 30 41.4 2 2730 CUT
           
Code No. of Pairs External diameter Wire armor diameter Cable weight Packing*
No.
    N x mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :1.5
73115 1 13.5 0.9 325 CUT
73215 2 17.7 0.9 485 CUT
73315 3 18.7 0.9 550 CUT
73415 4 20.2 0.9 435 CUT
73515 5 22.4 1.25 560 CUT
73615 6 24.2 1.25 955 CUT
73715 7 24.2 1.25 1000 CUT
731015 10 30.4 1.6 1515 CUT
731215 12 31.3 1.6 1625 CUT
731615 16 34.4 1.6 1945 CUT
732015 20 38.8 2 2520 CUT
732415 24 42.6 2 2905 CUT
733015 30 46.3 2.5 3760 CUT
Cross Section :2.5
73125 1 14.8 0.9 385 CUT
73225 2 19.9 0.9 590 CUT
73325 3 21.7 1.25 820 CUT
73425 4 23.5 1.25 945 CUT
73525 5 25.3 1.25 1065 CUT
73625 6 27.4 1.25 1215 CUT
73725 7 27.4 1.25 1280 CUT
731025 10 35.5 2 2165 CUT
731225 12 36.7 2 2350 CUT
731625 16 40.2 2 2805 CUT
732025 20 46 2.5 3730 CUT
732425 24 50.5 2.5 4270 CUT
733025 30 54.6 3.15 5490 CUT
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length`
Technical data
Flame Temperature Range MUTUAL CAPACITY (Max) Insulation  Thickness (Nom) Insulation  Resistance (Min) Conductor Resistance class2(Max)
  Propagation
IEC 60332-3-24 -30ºC~+70ºC (FIXED LAYING) pF/m mm2   mm MΩxKm Ω/km mm2
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24 250 0.5 0.6 5000 36 0.5
0.75 0.6 24.5 0.75
1 0.6 18.1 1
1.5 0.6 12.1 1.5
2.5 0.7 7.41 2.5
 
Bending Radius Test Voltage Operating Voltage Current L/R(Ratio) (Max)
Load(25ºC)
7, 5 X Cable Ø C r. /C r. =2 0 0 0 V 300/500V A mm2 µH /Ω mm2
Cr./Scrn.=2000 V 6 0.5 25 0.5
13 0.75 25 0.75
16 1 25 1
20 1.5 40 1.5
25 2.5 60 2.5
Temperature Range               Fixed -40 °C to+70 °C ; During Installation -5 °C -+50 °C
Flame Test                                  IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2)
Design Standards
IEC 60092-376
EN 50288-7
DIN VDE 819-7
Conductor   Annealed Copper or Tinned Copper - Class 2 Acc to IEC 60228 / HD 383 / DIN VDE 0295
Insulation XLPE acc to EN 50290-2
Insulation Color Code Pair : white, Black (numbered)
Triple :White, Black , Red (Numbered)
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2 PVC Compound
Armour Galvanized Round Steel Wire
Sheathing PVC compound Type YM1 UV Resistant and Flame retardant Acc to EN 0290-2
Color Black, Red, Blue Or by resuest

 

 

able with protective screen against electromagnetic impacts, for reliable and quick (up to 200 kB/s) transmission of analogue and digital signals, suitable for fixed and mobile installations in process control and data processing systems, mostly in chemical and petrochemical industrial plants and electric power plants. Low values of signal attenuation and low mutual capacitance enable large-distance signal transmission. Laid in dry and damp premises, also outdoor, in air or ground. Not intended for supply purposes