PHONE : 982144972925-7+

RE-2X(ST)YRY TIMF

RE-2X(St)YRY TIMF 
Code No. of elements External diameter Insulation thickness Cable weight Packing*
.No
    N x mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :0.5
7515 1 12.7 0.9 295 CUT
7525 2 18.1 0.9 485 CUT
7535 3 19.2 0.9 555 CUT
7545 4 21.4 1.25 755 CUT
7555 5 22.9 1.25 850 CUT
7565 6 24.8 1.25 950 CUT
7575 7 24.8 1.25 990 CUT
5105 10 31.3 1.6 1490 CUT
75125 12 32.2 1.6 1610 CUT
75165 16 36.2 2 2150 CUT
75205 20 39.9 2 2485 CUT
75245 24 45.2 2.5 3310 CUT
75305 30 47.7 2.5 3665 CUT
Cross Section :0.75
7517 1 13.4 0.9 320 CUT
7527 2 19.2 0.9 530 CUT
7537 3 20.1 0.9 605 CUT
7547 4 22.4 1.25 835 CUT
7557 5 24.3 1.25 950 CUT
7567 6 26.1 1.25 1055 CUT
7577 7 26.1 1.25 1100 CUT
75107 10 33.2 1.6 1670 CUT
75127 12 34.1 1.6 1805 CUT
75167 16 38.4 2 2420 CUT
75207 20 42.4 2 2800 CUT
75247 24 48 2.5 3710 CUT
75307 30 50.4 2.5 4110 CUT
Cross Section :1.0
75110 1 13.8 0.9 345 CUT
75210 2 19.9 0.9 570 CUT
75310 3 21.6 1.25 780 CUT
75410 4 23.5 1.25 905 CUT
75510 5 25.3 1.25 1025 CUT
75610 6 27.2 1.25 1140 CUT
75710 7 27.2 1.25 1195 CUT
751010 10 35.4 2 2075 CUT
751210 12 36.5 2 2225 CUT
751610 16 40.1 2 2635 CUT
752010 20 45.7 2.5 3535 CUT
752410 24 50.2 2.5 4040 CUT
753010 30 53 2.5 4555 CUT
           
Code No. of elements External diameter Insulation thickness Cable weight Packing*
.No
    N x mm² .approx nominal .approx  
  mm mm kg/km  
Cross Section :1.5
75115 1 14.4 0.9 385 CUT
75215 2 21.8 1.25 765 CUT
75315 3 23.1 1.25 895 CUT
75415 4 25 1.25 1025 CUT
75515 5 26.9 1.25 1170 CUT
75615 6 29.9 1.6 1515 CUT
75715 7 29.9 1.6 1590 CUT
751015 10 38.1 2 2375 CUT
751215 12 39.2 2 2595 CUT
751615 16 44.5 2.5 3545 CUT
752015 20 49.1 2.5 4125 CUT
752415 24 54 2.5 4710 CUT
753015 30 58.4 3.15 6025 CUT
Cross Section :2.5
75125 1 15.8 0.9 455 CUT
75225 2 24.5 1.25 935 CUT
75325 3 25.9 1.25 1090 CUT
75425 4 28.9 1.6 1460 CUT
75525 5 31.4 1.6 1675 CUT
75625 6 33.9 1.6 1895 CUT
75725 7 33.9 1.6 2000 CUT
751025 10 44.7 2.5 3450 CUT
751225 12 46.1 2.5 3785 CUT
751625 16 50.9 2.5 4500 CUT
752025 20 57.9 1.15 6005 CUT
752425 24 63.9 3.15 6890 CUT
753025 30 67.2 3.15 7790 CUT
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length`
Technical data
Flame Temperature Range MUTUAL CAPACITY (Max) Insulation  Thickness (Nom) Insulation  Resistance (Min) Conductor Resistance class2(Max)
  Propagation
IEC 60332-3-24 -30ºC~+70ºC (FIXED LAYING) pF/m mm2   mm MΩxKm Ω/km mm2
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24 250 0.5 0.6 100 36 0.5
0.75 0.6 24.5 0.75
1 0.6 18.1 1
1.5 0.6 12.1 1.5
2.5 0.7 7.41 2.5
 
Bending Radius Test Voltage Operating Voltage Current L/R(Ratio) (Max)
Load(25ºC)
7, 5 X Cable Ø C r. /C r. =2 0 0 0 V 300/500V A mm2 µH /Ω mm2
Cr./Scrn.=2000 V 6 0.5 25 0.5
13 0.75 25 0.75
16 1 25 1
20 1.5 40 1.5
25 2.5 60 2.5
Temperature Range               Fixed -40 °C to+70 °C ; During Installation -5 °C -+50 °C
Flame Test                                  IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2)
Design Standards
IEC 60092-376
EN 50288-7
DIN VDE 819-7

 

Conductor   Annealed Copper or Tinned Copper - Class 2 Acc to IEC 60228 / HD 383 / DIN VDE 0295
Insulation XLPE acc to EN 50290-2
Insulation Color Code Pair : white, Black (numbered)
Triple :White, Black , Red (Numbered)
Ind. Screen  PES Tape +TINNED COPPER DRAIN WIRE; AL-PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2 PVC Compound
Armour Galvanized Round Steel Wire
Sheathing PVC compound Type YM1 UV Resistant and Flame retardant Acc to EN 0290-2
Color Black, Red, Blue Or by resuest


 

Cable with protective screen against electromagnetic impacts, for reliable and quick (up to 200 kB/s) transmission of analogue and digital signals, suitable for fixed and mobile installations in process control and data processing systems, mostly in chemical and petrochemical industrial plants and electric power plants. Low values of signal attenuation and low mutual capacitance enable large-distance signal transmission. Laid in dry and damp premises, also outdoor, in air or ground. Not intended for supply purposes