Cross Section :0.5
7215 1 12.3 0.9 280 CUT
7225 2 16.8 0.9 425 CUT
7235 3 17.6 0.9 475 CUT
7245 4 19.1 0.9 540 CUT
7255 5 20.4 0.9 615 CUT
7265 6 22.6 1.25 815 CUT
7275 7 22.6 1.25 840 CUT
72105 10 28.6 1.6 1275 CUT
72125 12 29.4 1.6 1375 CUT
72165 16 32.1 1.6 1600 CUT
72205 20 36.1 2 2105 CUT
72245 24 39.6 2 2400 CUT
72305 30 41.6 2 2665 CUT
Cross Section :0.75
7217 1 12.7 0.9 295 CUT
7227 2 17.5 0.9 460 CUT
7237 3 18.6 0.9 525 CUT
7247 4 20 0.9 595 CUT
7257 5 22.1 1.25 805 CUT
7267 6 23.9 1.25 905 CUT
7277 7 23.9 1.25 940 CUT
72107 10 30.1 1.6 1410 CUT
72127 12 31 1.6 1525 CUT
72167 16 34 1.6 1785 CUT
72207 20 38.3 2 2345 CUT
72247 24 41.9 2 2660 CUT
72307 30 45.6 2.5 3440 CUT
Cross Section :1.0
72110 1 1.3 0.9 315 CUT
72210 2 18.4 0.9 495 CUT
72310 3 19.3 0.9 560 CUT
72410 4 21.4 1.25 765 CUT
72510 5 23.2 1.25 870 CUT
72610 6 24.9 1.25 970 CUT
72710 7 24.9 1.25 1010 CUT
721010 10 31.4 1.6 1520 CUT
721212 12 32.3 1.6 1645 CUT
721616 16 36.3 2 2195 CUT
722020 20 40 2 2545 CUT
722424 24 45.4 2.5 3380 CUT
723030 30 47.9 2.5 3950 CUT
           
Code No. of pairs External diameter Armour wire diameter Cable weight Packing*
.No
    N x mm² approx. nominal approx.  
  mm mm kg/km  
Cross Section :1.5
72115 1 13.9 0.9 345 CUT
72215 2 19.5 0.9 550 CUT
72315 3 20.4 0.9 635 CUT
72415 4 22.9 1.25 870 CUT
72515 5 24.7 1.25 980 CUT
72615 6 26.5 1.25 2000 CUT
72715 7 26.5 1.25 1155 CUT
721015 10 33.7 1.6 1745 CUT
721215 12 35.5 2 2145 CUT
721615 16 39 2 2540 CUT
722015 20 44.5 2.5 3410 CUT
722415 24 48.8 2.5 3895 CUT
723015 30 51.5 2.5 4385 CUT
Cross Section :2.5
72125 1 15.1 0.9 405 CUT
72225 2 22.6 1.25 810 CUT
72325 3 32.7 1.25 915 CUT
72425 4 25.6 1.25 1060 CUT
72525 5 28.5 1.6 1380 CUT
72625 6 30.7 1.6 1550 CUT
72725 7 30.7 1.6 1625 CUT
721025 10 39.1 2 2460 CUT
721225 12 40.3 2 2680 CUT
721625 16 46 2.5 3650 CUT
722025 20 50.8 2.5 4275 CUT
722425 24 57.1 3.15 5532 CUT
723025 30 60.7 3.15 6295 CUT
Technical data
Flame Temperature Range MUTUAL CAPACITY (Max) Insulation  Thickness (Nom) Insulation  Resistance (Min) Conductor Resistance class2(Max)
  Propagation
IEC 60332-3-24 -30ºC~+70ºC (FIXED LAYING) pF/m mm2   mm MΩxKm Ω/km mm2
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24 250 0.5 0.6 5000 36 0.5
0.75 0.6 24.5 0.75
1 0.6 18.1 1
1.5 0.6 12.1 1.5
2.5 0.7 7.41 2.5
 
Bending Radius Test Voltage Operating Voltage Current L/R(Ratio) (Max)
Load(25ºC)
7, 5 X Cable Ø C r. /C r. =2 0 0 0 V 300/500V A mm2 µH /Ω mm2
Cr./Scrn.=2000 V 6 0.5 25 0.5
13 0.75 25 0.75
16 1 25 1
20 1.5 40 1.5
25 2.5 60 2.5
Temperature Range               Fixed -40 °C to+70 °C ; During Installation -5 °C -+50 °C
Flame Test                                  IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2)
Design Standards
IEC 60092-376
EN 50288-7
DIN VDE 819-7

 

Conductor   Annealed Copper or Tinned Copper - Class 2 Acc to IEC 60228 / HD 383 / DIN VDE 0295
Insulation XLPE acc to EN 50290-2
Insulation Color Code Pair : white, Black (numbered)
Triple :White, Black , Red (Numbered)
Ind. Screen  PES Tape +TINNED COPPER DRAIN WIRE; AL-PES TAPE
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2 PVC Compound
Armour Galvanized Round Steel Wire
Sheathing PVC compound Type YM1 UV Resistant and Flame retardant Acc to EN 0290-2
Color Black, Red, Blue Or by resuest

 

 

Cable with protective screen against electromagnetic impacts, for reliable and quick (up to 200 kB/s) transmission of analogue and digital signals, suitable for fixed and mobile installations in process control and data processing systems, mostly in chemical and petrochemical industrial plants and electric power plants. Low values of signal attenuation and low mutual capacitance enable large-distance signal transmission. Laid in dry and damp premises, also outdoor, in air or ground. Not intended for supply purposes