PHONE : 982144972925-7+

RE-2X(ST)YRY MultiTriple

(RE-2X(St)YRY Multi Triple (0.5-2.5
Code No. of cores External diameter Armour Wire Diameter Cable weight Packing*
No.
N x mm² .approx nominal .approx
mm mm kg/km
Cross Section :0.5
7115 1 12.4 0.9 280 CUT
7125 2 16.6 0.9 425 CUT
7135 3 17.4 0.9 475 CUT
7145 4 18.9 0.9 545 CUT
7155 5 20.2 0.9 610 CUT
7165 6 22.3 1.25 805 CUT
7175 7 22.3 1.25 830 CUT
71105 10 27.4 1.25 2000 CUT
71125 12 29 1.6 1365 CUT
71165 16 31.6 1.6 1590 CUT
71205 20 35.7 2 2085 CUT
71245 24 39.1 2 2380 CUT
71305 30 41.1 2 2655 CUT
Cross Section :0.75
7117 1 12.8 0.9 300 CUT
7127 2 17.4 0.9 465 CUT
7137 3 18.4 0.9 530 CUT
7147 4 19.8 0.9 605 CUT
7157 5 22 1.25 820 CUT
7167 6 23.7 1.25 910 CUT
7177 7 23.7 1.25 945 CUT
71107 10 29.8 1.6 1440 CUT
71127 12 30.7 1.6 1545 CUT
71167 16 33.7 1.6 1820 CUT
71207 20 38 2 2385 CUT
71247 24 41.5 2 2710 CUT
71307 30 45.2 2.5 3535 CUT
Cross Section :1.0
71110 1 13.4 0.9 325 CUT
71210 2 18.1 0.9 500 CUT
71310 3 19.2 0.9 580 CUT
71410 4 21.3 1.25 790 CUT
71510 5 22.9 1.25 890 CUT
71610 6 24.7 1.25 1005 CUT
71710 7 24.7 1.25 1050 CUT
711010 10 31.2 1.6 1575 CUT
711210 12 32.1 1.6 1715 CUT
711610 16 36.1 2 2290 CUT
712010 20 39.8 2 2660 CUT
712410 24 44.7 2.5 3440 CUT
713010 30 47.6 2.5 3925 CUT
           
Code No. of cores External diameter Armour Wire Diameter Cable weight Packing*
No.
N x mm² .approx nominal .approx
mm mm kg/km
Cross Section :1.5
71115 1 14 0.9 361 CUT
71215 2 19.4 0.9 575 CUT
71315 3 20.4 0.9 665 CUT
71415 4 22.9 1.25 910 CUT
71515 5 24.6 1.25 1035 CUT
71615 6 26.4 1.25 1165 CUT
71715 7 26.4 1.25 1235 CUT
711015 10 33.6 1.6 1860 CUT
711215 12 35.4 2 2280 CUT
711615 16 38.9 2 2720 CUT
712015 20 44.4 2.5 3635 CUT
712415 24 48.6 2.5 4125 CUT
713015 30 51.4 2.5 4680 CUT
Cross Section :2.5
71125 1 15.4 0.9 430 CUT
71225 2 22.6 1.25 850 CUT
71325 3 23.8 1.25 980 CUT
71425 4 25.7 1.25 1150 CUT
71525 5 28.6 1.6 1490 CUT
71625 6 30.8 1.6 1675 CUT
71725 7 30.8 1.6 1775 CUT
711025 10 39.3 2 2675 CUT
711225 12 40.4 2 2935 CUT
711625 16 46.1 2.5 3989 CUT
712025 20 50.9 2.5 4705 CUT
712425 24 57.3 3.15 6045 CUT
713025 30 60.9 3.15 6940 CUT
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length`
Technical data
Flame Temperature Range MUTUAL CAPACITY (Max) Insulation  Thickness (Nom) Insulation  Resistance (Min) Conductor Resistance class2(Max)
  Propagation
IEC 60332-3-24 -30ºC~+70ºC (FIXED LAYING) pF/m mm2   mm MΩxKm Ω/km mm2
VDE 0482-332-3-24
EN 60332-3-24
BS EN 60332-3-24 250 0.5 0.6 5000 36 0.5
0.75 0.6 24.5 0.75
1 0.6 18.1 1
1.5 0.6 12.1 1.5
2.5 0.7 7.41 2.5
 
Bending Radius Test Voltage Operating Voltage Current L/R(Ratio) (Max)
Load(25ºC)
7, 5 X Cable Ø C r. /C r. =2 0 0 0 V 300/500V A mm2 µH /Ω mm2
Cr./Scrn.=2000 V 6 0.5 25 0.5
13 0.75 25 0.75
16 1 25 1
20 1.5 40 1.5
25 2.5 60 2.5
Temperature Range               Fixed -40 °C to+70 °C ; During Installation -5 °C -+50 °C
Flame Test                                  IEC/EN/BS/DIN 60332-1-2 (VDE 0482-332-1-2)
Design Standards
IEC 60092-376
EN 50288-7
DIN VDE 819-7
Conductor   Annealed Copper or Tinned Copper - Class 2 Acc to IEC 60228 / HD 383 / DIN VDE 0295
Insulation XLPE acc to EN 50290-2
Insulation Color Code Pair : white, Black (numbered)
Triple :White, Black , Red (Numbered)
Overall Screen TINNED COPPER DRAIN WIRE; AL-PES TAPE
Inner Sheath EN 50290-2 PVC Compound
Armour Galvanized Round Steel Wire
Sheathing PVC compound Type YM1 UV Resistant and Flame retardant Acc to EN 0290-2
Color Black, Red, Blue Or by resuest

 

 

  • Instrumentation and control engineering analog and digital signal transmission
  • Petroleum refineries
  • Petrochemistry industry
  • Power plants
  • Natural gas pump stations
  • Indoors and outdoors, dry, damp and wet environments
  • Gas Stations
  • Water Conveyance Systems