PHONE : 982144972925-7+

NYMHY

300/500V(Generally as IEC 60227)
.Code No number of cores x conductor cross-section Construction of individual conductor External diameter Insulation thickness Sheath thickness Conductor resistance at 20 °C Cable weight Packing**
nominal min-max. nominal nominal max. approx.
  mm² n x mm mm mm mm Ω/km kg/km  
13275 2x 0.75 24x 0.195 5.7-7.2 0.6 0.8 26 52 c.100
13210 2x 1.0 31x 0.195 5.9-7.5 0.6 0.8 19.5 65 c.100
13215 2x 1.5 31x 0.23 6.8-8.6 0.7 0.8 13.3 90 c.100
13225 2x 2.5 51x 0.23 8.4-10.6 0.8 1 7.98 115 c.100
13240 2x 4 83x0.23 10.2-10.6 0.8 1 4.95 183 c.100
13260 2x 6 82x0.28 11.6-12.0 0.8 1.1 3.3 258 c.100
132100 2x10 70x0.395 15.4-15.8 1 1.2 1.91 442 c.100
132160 2x16 118x0.395 18.2-18.6 1 1.6 1.21 696 CUT
132250 2x25 186x0.395 22.2-22.6 1.2 1.8 0.78 965 CUT
13375 3x 0.75 24x 0.195 6.0-7.6 0.6 0.8 26 70 c.100
13310 3x 1.0 31x 0.195 6.3-8.0 0.6 0.8 19.5 80 c.100
13315 3x 1.5 31x 0.23 7.4-9.4 0.7 0.9 13.3 115 c.100
13325 3x 2.5 51x 0.23 9.2-11.4 0.8 1.1 7.98 175 c.100
13340 3x 4 83x0.23 10.5-13.4 0.8 1.2 4.95 234 c.100
13360 3x 6 82x0.28 12.5-12.9 0.8 1.2 3.3 321 c.100
133100 3x10 70x0.395 17.0-17.4 1 1.5 1.91 585 c.100
133160 3x16 118x0.395 19.4-19.6 1 1.6 1.21 811 CUT
133250 3x25 186x0.395 23.6-24.0 1.2 1.8 0.78 1238 CUT
13475 4x 0.75 24x 0.195 6.6-8.3 0.6 0.8 26 75 c.100
13410 4x 1.0 31x 0.195 7.1-9.0 0.6 0.9 19.5 92 c.100
13415 4x 1.5 31x 0.23 8.4-10.5 0.7 1 13.3 145 c.100
13425 4x 2.5 51x 0.23 10.1-12.5 0.8 1.1 7.98 210 c.100
13440 4x 4 83x0.23 12.3-12.7 0.8 1.2 4.95 296 c.100
13460 4x 6 82x 0.28 14.7-15.0 0.8 1.2 3.3 480 c.100
134100 4x10 70x0.395 19.3-19.7 1 1.8 1.91 755 CUT
134160 4x16 118x0.395 21.7-22.1 1 1.8 1.21 998 CUT
134250 4x25 186x0.395 26.7-27.1 1.2 2.1 0.78 1586 CUT
13575 5x 0.75 24x 0.195 7.4-9.3 0.6 0.9 26 96 c.100
13510 5x 1.0 31x 0.195 7.8-9.8 0.6 0.9 19.5 113 c.100
13515 5x 1.5 31x 0.23 9.3-11.6 0.7 1.1 13.3 175 c.100
13525 5x 2.5 51x 0.23 11.2-13.9 0.8 1.2 7.98 260 c.100
13540 5x 4 83x0.23 16.1-16.7 0.8 1.4 4.95 363 c.100
13560 5x 6 82x 0.28 16.7-16.9 0.8 1.5 3.3 585 c.100
135100 5x10 70x0.395 21.2-21.6 1 1.8 1.91 934 CUT
135160 5x16 118x0.395 24.0-24.4 1 1.8 1.21 1285 CUT
135250 5x25 186x0.395 29.4-29.8 1.2 2.1 0.78 1976 CUT
*)Packing: c.100 = coil 100 m, CUT= cable in different lengths on drum or reel, possible cutting at required 
Temperature during installationi: +5 °C up to +70 °C
fixed installed Temperature: -30 °C up to +70 °C
Temperature at short circuit of max. 5 s: up to 150 °C
ambient temperature at storage: up to 40 °C
Nominal voltage: Uο/U = 300/500 V
Test voltage: 2000 V
Minimal inner bending radius: 4D for D < 8 mm 
5D for 8 - 12 mm 
6D for D > 12 mm
Behaviour in fire: IEC 60332-1


 

Conductor: bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: PVC compound TI2 acc. to DIN VDE 0207 part 4/ HD 21.1 S4, concentrically stranded cores color marked acc. to HRN HD 308 S2 / DIN VDE 0293-308, with or without yellow-green protective conductor
Sheath: PVC compound TM2 for flexible cables acc. to DIN VDE 0207 part 5 / HD 21.1 S4
sheath color: white or black(Ral 9005)
Core color marking: HRN HD 308 S2 / VDE 0293-308

Flexible cable for medium mechanical stresses. Permitted frequent bending and twisting. Specially suitable for application in household, kitchens and offices in dry and damp conditions, for inst. washing-machines, dryers, refrigerators etc., as long as the cable is adapted to essential specifications of the device. Also suitable for cookers, i.e. hot devices, on condition that it does not get in direct contact with hot parts of the device and is not exposed to heat irradiation. Suitable for fixed installation in furniture, partition walls, decorative linings and cavities in prefabricated construction elements.