PHONE : 982144972925-7+

NYM

    NYM 2 X (1.5-35)mm2  
Code No  number of cores x conductor cross-section Construction* Construction of individual conductor External diameter Conductor resistance at 20 °C Cable weight Current-Carrying Capacityat 30°C *in air Packing**
(MM) Kg/Km
      nominal min-max. max. nominal Max. (A)  
122150 2x 1,5 RE 1x 1,36 8,4 - 9,8 12,10 115 19 c.100
122151 2x 1,5 RM 7x 0.52 9,0 - 9,4 12,10 130 19 c.100
122250 2x 2,5 RE 1x 1,78 9.8 – 10.4 7.41 164 25 c.100
122251 2x 2,5 RM 7x 0.66 10.3 – 10.6 7.41 177 25 c.100
122400 2x 4 RE 1x 2.2 10.7 - 11,1 4.61 213 34 c.100
122401 2x 4 RM 7x 0.85 11,3 – 11.7 4,61 232 34 c.100
122600 2x 6 RE 1x 2.7 11.7 – 12.1 3.08 274 44 c.100
122601 2x 6 RM 7x 1.04 12.4 – 12.8 3.08 298 44 c.100
1221000 2x 10 RE 1x 3.49 14.9– 15.3 1.83 446 61 c.100
1221001 2x 10 RM 7x 1.35 15.9 – 16.3 1.83 492 61 c.100
1221601 2x 16 RM 7x 1.7 18– 18.4 1.15 678 82 CUT
1222501 2x 25 RM 7x 2.2 21.8 – 22.4 0.727 1061 108 CUT
1223501 2x 35 RM 7x 2.6 23.8 – 24.2 0.524 1319 134 CUT
                 
                 
NYM 3 X (1.5-35)mm2
Code No  number of cores x conductor cross-section Construction* Construction of individual conductor External diameter Conductor resistance at 20 °C Cable weight Current-Carrying Capacityat 30°C *in air Packing**
(MM) Kg/Km
      nominal min-max. max. nominal Max. (A)  
123150 3x 1,5 RE 1x 1,36 9 - 9,4 12,10 139 19 c.100
123151 3x 1,5 RM 7x 0.52 9,4 - 9,8 12,10 151 19 c.100
123250 3x 2,5 RE 1x 1,78 10.3 – 10.7 7.41 193 25 c.100
123251 3x 2,5 RM 7x 0.66 10.8 – 11.2 7.41 207 25 c.100
123400 3x 4 RE 1x 2.2 11.3 - 11,7 4.61 255 34 c.100
123401 3x 4 RM 7x 0.85 11,9 – 112.3 4,61 276 34 c.100
123600 3x 6 RE 1x 2.7 12.8 – 13.2 3.08 345 44 c.100
123601 3x 6 RM 7x 1.04 13.6 – 14 3.08 374 44 c.100
1231000 3x 10 RE 1x 3.49 15.7– 16.1 1.83 544 61 CUT
1231001 3x 10 RM 7x 1.35 16.8 – 17.1 1.83 597 61 CUT
1231601 3x 16 RM 7x 1.7 19.5– 19.9 1.15 861 82 CUT
1232501 3x 25 RM 7x 2.2 23.6 – 30 0.727 1321 108 CUT
1233501 3x 35 RM 7x 2.6 25.2 – 25.6 0.524 1636 134 CUT
                 
NYM 4 X (1.5-35)mm2
Code No

number of cores x conductor cross-section

Construction* Construction of individual conductor External diameter Conductor resistance at 20 °C Cable weight Current-Carrying Capacityat 30°C *in air Packing**
(MM) Kg/Km
      nominal min-max. max. nominal Max. (A)  
124150 4x 1,5 RE 1x 1,36 9.7-10.1 12,10 164 19 c.100
124151 4x 1,5 RM 7x 0.52 10.2-10.6 12,10 179 19 c.100
124250 4x 2,5 RE 1x 1,78 11.2-11.6 7.41 232 25 c.100
124251 4x 2,5 RM 7x 0.66 11.7-12.1 7.41 248 25 c.100
124400 4x 4 RE 1x 2.2 12.7-13.1 4.61 321 34 c.100
124401 4x 4 RM 7x 0.85 13.4-13.8 4,61 346 34 c.100
124600 4x 6 RE 1x 2.7 14.3-14.7 3.08 438 44 c.100
124601 4x 6 RM 7x 1.04 15.3-15.7 3.08 473 44 c.100
1241000 4x 10 RE 1x 3.49 17.2-17.6 1.83 668 61 CUT
1241001 4x 10 RM 7x 1.35 18.4-18.8 1.83 731 61 CUT
1241601 4x 16 RM 7x 1.7 21.3-21.7 1.15 1059 82 CUT
1242501 4x 25 RM 7x 2.2 26.3-26.7 0.727 1651 108 CUT
1243501 4x 35 RM 7x 2.6 27.7-28.1 0.524 2019 134 CUT
                 
NYM 5 X (1.5-35)mm2
Code No  number of cores x conductor cross-section Construction* Construction of individual conductor External diameter Conductor resistance at 20 °C Cable weight Current-Carrying Capacityat 30°C *in air Packing**
(MM) Kg/Km    
      nominal min-max. max. nominal Max. (A)  
125150 5x 1,5 RE 1x 1,36 10.5-10.9 12,10 196 19 c.100
125151 5x 1,5 RM 7x 0.52 11.1-11.5 12,10 214 19 c.100
125250 5x 2,5 RE 1x 1,78 12.1-12.5 7.41 279 25 c.100
125251 5x 2,5 RM 7x 0.66 12.8-13.2 7.41 299 25 c.100
125400 5x 4 RE 1x 2.2 14.2-14.6 4.61 404 34 c.100
125401 5x 4 RM 7x 0.85 15-15.4 4,61 436 34 c.100
125600 5x 6 RE 1x 2.7 15.6-16 3.08 531 44 c.100
125601 5x 6 RM 7x 1.04 16.5-19.9 3.08 572 44 c.100
1251000 5x 10 RE 1x 3.49 18.8-19.2 1.83 814 61 CUT
1251001 5x 10 RM 7x 1.35 20.1-20.5 1.83 892 61 CUT
1251601 5x 16 RM 7x 1.7 23.8-24.2 1.15 1319 82 CUT
1252501 5x 25 RM 7x 2.2 28.8-29.2 0.727 1962 108 CUT
1253501 5x 35 RM 7x 2.6 30.4-30.8 0.524 2416 134 CUT
 *)Packing: c.100 = coil 100 m, CUT= cable in different lengths on drum or reel, possible cutting at required  
                 
Temperature during installationi: +5 °C up to +70 °C
fixed installed Temperature : -30 °C up to +70 °C
Temperature at short circuit of max. 5 s: up to 150 °C
Nominal voltage: Uο/U = 300/500 V
Ispitni napon: 2000 V
Minimal inner bending radius: 6D
Behaviour in fire: IEC 60332-1

 

Conductor Insulation Inductance Current - Carrying Capacity at 30° C * Short circuit current at 1 sec
Nom. Cross Section Area DC Resistance at 20°C AC Resistance at 70°C Insulation Resistance
at 70°C in air
(mm²)
Max. (Ω/km)
Max. (Ω/km)
Min.  (mH/km) Max. (A) Max. (kA)
(M.Ω.km)
1.5 12.1 14.478 0.01 0.329 19 0.17
2.5 7.41 8.866 0.009 0.318 25 0.29
4 4.61 5.516 0.0077 0.297 34 0.46
6 3.08 3.685 0.0065 0.281 44 0.69
10 1.83 2.19 0.0065 0.278 61 1.15
16 1.15 1.376 0.0052 0.255 82 1.84
25 0.727 0.87 0.005 0.252 108 2.88
35 0.524 0.627 0.0044 0.244 134 4.03
Conductor: bare copper conductor acc. to IEC 60228 / HD 383 / DIN VDE 0295
class 1: solid (RE construction)
class 2: multi wire stranded (RM construction)
Insulation: PVC compound TI1 acc. to DIN VDE 0281 part 1 / HD 21.1 S4
Filler: cores enveloped in non-vulcanized rubber or plastic compound
Sheath: PVC compound TM1 acc. to DIN VDE 0281 part 1 / HD 21.1 S4
sheath colour: Black or Grey

Installation cable suitable for household and industrial usage. Laid on or under plaster, in walls or concrete, without special mechanical protection, but not in dry or pre-stressed concrete. Suitable for dry, same as damp or wet environment; for internal or external application (only if the cable is protected against direct sunlight).