PHONE : 982144972925-7+

J-H(St)H

J-H(St)H
  • Min Installation Temperature -5°C
  • halogen- free cable
  • low Smoke Acc to IEC 61034
  • Flame Retardant acc to IEC 60332-3-24
cores x conductor diameter External diameter Fire load Cable weight Packing*
  approx.   approx.  
N x mm² mm kWh/m kg/km  
Conductor :0.6mm
2 x 2 x 0,6 5,4 0,18 50 CUT
4 x 2 x 0,6 6,9 0,31 91 CUT
6 x 2 x 0,6 7,6 0,32 105 CUT
10 x 2 x 0,6 9,5 0,41 150 CUT
20 x 2 x 0,6 11,2 0,67 315 CUT
30 x 2 x 0,6 13,1 0,91 350 CUT
40 x 2 x 0,6 15,5 1,15 465 CUT
50 x 2 x 0,6 17,5 1,46 575 CUT
60 x 2 x 0,6 18,5 1,67 660 CUT
80 x 2 x 0,6 20,2 2,15 878 CUT
100 x 2 x 0,6 23,2 2,65 1054 CUT
Conductor :0.8mm
2 x 2 x 0,8 7,4 0,22 70 CUT
4 x 2 x 0,8 9,6 0,37 135 CUT
6 x 2 x 0,8 10,2 0,43 155 CUT
10 x 2 x 0,8 13,2 0,60 235 CUT
20 x 2 x 0,8 16,6 0,95 510 CUT
30 x 2 x 0,8 20,1 1,38 610 CUT
40 x 2 x 0,8 22,5 1,73 780 CUT
50 x 2 x 0,8 25,6 2,05 980 CUT
60 x 2 x 0,8 28,5 2,48 1120 CUT
80 x 2 x 0,8 31,8 3,14 1475 CUT
100 x 2 x 0,8 32,0 3,91 1810 CUT
during installation: -5 °C up to +50 °C
fixed installed: -30 °C up to +70 °C
Operating voltage: max. 300 V
Test voltage:  
core - core: 800 V
core - screen: 800 V
Insulation resistance: min. 100 MΩxkm
Mutual capacitance: (at 800 Hz) max. 300 pF/100m
Min. inner bending radius:  
during laying or with repeated bending with stress: 7,5D
single bending without stress: 2,5D
Flame retardant: IEC 60332-1
No flame propagation in vertical cable bundle: IEC 60332-3
Halogen-free: IEC 60754-1
Non-corrosive combustion gases: IEC 60754-2
Low smoke density: IEC 61034-2
Conductor: bare solid copper conductor, of 0,6 or 0,8 mm diameter
Insulation: halogen-free polyolefin compound HI2, acc. to DIN VDE 0207 part 23, of 0,3 or 0,4 mm thickness, per four conductors are stranded in star-quad, each 5 quads are stranded in bundle, and bundles are stranded in layers, core colour marking is defined acc. to DIN VDE 0815
Separator: PEPT - plastic tape of poly (ethylene/propylene) or polyester tape
Electrostatic screen: aluminium - laminated polyester tape or tinned copper contact conductor of 0,6 or 0,8 mm diameter
Sheath: halogen-free polyolefin compound HM2 acc. to DIN VDE 0207 part 24
sheath colour: Red (RAL 3020)

Halogen-free installation cable for transmission of telephone and data (analogue and digital) signals, with improved properties under fire. Electrostatic screen protects transmission circuits against external disturbing electromagnetic impact. Suitable for fixed installation in dry or damp premises where people and material goods need to be protected in case of fire. Recommended for public and industrial facilities where a lot of people is gathering, and for facilities of high material value. Not for direct laying in ground or water, not for outdoor application (except when protected against sunlight), not intended for supply purposes.

advantages:
- halogen-free, no release of toxic and corrosive gases under fire
- reduced smoke manifestation under fire
- no flame propagation in vertical cable bundle , flame retardant