PHONE : 982144972925-7+

HSLCH

Cable code number of cores x conductor cross-section Construction of individual conductor External diameter Conductor resistance at 20 °C Cable weight Packing*
    nominal approx. max. approx.  
  N x mm² n x mm mm Ω/km kg/km  
Cross section :0.5mm²
625 2 x 0,5 16 x 0,20 5.8 39,00 50 CUT
635 3 x 0,5 16 x 0,20 6.2 39,00 60 CUT
645 4 x 0,5 16 x 0,20 6.7 39,00 65 CUT
655 5 x 0,5 16 x 0,20 7.1 39,00 85 CUT
675 7 x 0,5 16 x 0,20 8.9 39,00 110 CUT
6125 12 x 0,5 16 x 0,20 10 39,00 165 CUT
6185 18 x 0,5 16 x 0,20 11.9 39,00 230 CUT
61255 25 x 0,5 16 x 0,20 13.2 39,00 320 CUT
Cross section :0.75mm²
61275 2 x 0,75 24 x 0,20 6.5 26,00 60 CUT
61375 3 x 0,75 24 x 0,20 6.8 26,00 75 CUT
61475 4 x 0,75 24 x 0,20 8.1 26,00 85 CUT
61575 5 x 0,75 24 x 0,20 8.9 26,00 105 CUT
61775 7 x 0,75 24 x 0,20 9.6 26,00 130 CUT
611275 12 x 0,75 24 x 0,20 11.5 26,00 210 CUT
Cross section :1.0mm²
61210 2 x 1,0 32 x 0,20 6.7 19,50 65 CUT
61310 3 x 1,0 32 x 0,20 7.1 19,50 85 CUT
61410 4 x 1,0 32 x 0,20 7.4 19,50 100 CUT
61510 5 x 1,0 32 x 0,20 8.6 19,50 120 CUT
61710 7 x 1,0 32 x 0,20 9.8 19,50 165 CUT
611210 12 x 1,0 32 x 0,20 11.9 19,50 250 CUT
611810 18 x 1,0 32 x 0,20 19.2 19,50 375 CUT
612510 25 x 1,0 32 x 0,20 16.8 19,50 510 CUT
Cross section :1.5mm²
61315 3 x 1,5 30 x 0,25 7.8 13,30 120 CUT
61415 4 x 1,5 30 x 0,25 8.1 13,30 130 CUT
61515 5 x 1,5 30 x 0,25 8.6 13,30 185 CUT
61715 7 x 1,5 30 x 0,25 11.8 13,30 235 CUT
611215 12 x 1,5 30 x 0,25 13.2 13,30 360 CUT
611815 18 x 1,5 30 x 0,25 15.8 13,30 510 CUT
612515 25 x 1,5 30 x 0,25 19.2 13,30 690 CUT
Cross section :2.5mm²
61225 2 x 2,5 50 x 0,25 8.6 7,98 135 CUT
61325 3 x 2,5 50 x 0,25 9.8 7,98 165 CUT
61425 4 x 2,5 50 x 0,25 10.1 7,98 195 CUT
Cross section :4mm²
6124 2 x 4 56 x 0,30 10.8 4,95 210 CUT
6134 3 x 4 56 x 0,30 10.9 4,95 250 CUT
6144 4 x 4 56 x 0,30 12.1 4,95 290 CUT
6174 7 x 4 56 x 0,30 15.4 4,95 490 CUT
Cross section :6mm²
6126 2 x 6 84 x 0,30 11.8 3,30 280 CUT
6136 3 x 6 84 x 0,30 12.9 3,30 345 CUT
6146 4 x 6 84 x 0,30 14.8 3,30 400 CUT
6176 7 x 6 84 x 0,30 19.8 3,30 685 CUT
Cross section :10mm²
61210 2 x 10 80 x 0,40 15.1 1,91 450 CUT
61310 3 x 10 80 x 0,40 15.8 1,91 500 CUT
61410 4 x 10 80 x 0,40 17.9 1,91 700 CUT
61510 5 x 10 80 x 0,40 19.8 1,91 825 CUT
61710 7 x 10 80 x 0,40 21.8 1,91 1260 CUT
Temperature during installation: -5 °C up to +50 °C
fixed installed Temperature : -20 °C up to +70 °C
max. operating temperature: 70 °C
at short circuit of max. 5 s: up to 150 °C
Nominal voltage: Uο/U = 300/500 V
Test voltage: 2000 V
Minimal inner bending radius:  
fixed installation: 4D
mobile installation: 15D
Flame retardant: IEC 60332-1
No flame propagation in vertical cable bundle: IEC 60332-3
Halogen-free: IEC 60754-1
Non-corrosive combustion gases: IEC 60754-2
Low smoke density: IEC 61034-2
Conductor: bare copper conductor, fine wired, stranded in layers, class 5 acc. to.  IEC 60228 / DIN VDE 0295
Insulation: halogen-free polyolefin polymer, concentrically stranded cores
Separator: polyester foil
Concentric conductor: braid of tinned copper wires, overlap >65%
Sheath:  halogen-free polyolefin Compound ST8 Acc to IEC60502-1
sheath colour: light grey (for inst. RAL 7001 or RAL 7035)
Core colour marking: acc. to  VDE 0293-308

Halogen-free signal cable with improved properties under fire, suitable for different applications in control and measuring circuits, in industry and facilities where human lives or valuable property need to be protected against damages caused by fire. Concentric copper conductor serves as screen against electromagnetic impact. Suitable for fixed and mobile installation, but free of mechanical stress; for dry and damp environment, not for outdoor application. Resistant to majority of most frequently used oils.

advantages:
- halogen-free, no release of toxic or corrosive gases under fire
- reduced smoke occurrence under fire
- no flame propagation in vertical cable bundle