PHONE : 982144972925-7+

J-2Y(St)H

J-2Y(St)H
  • Max Conductor Temperature 70 'C
  • Operating Voltage
  • low Smoke Acc to IEC 61034
  • HFFR - Telecommunication Cable
  • not applicable for power
  •  Flame Retardant acc to IEC 60332-3-24
Code No. No. of Cores x  Approx. Outer Diameter  Approx. Cable Weight
Cross Section
  mm mm Kg/Km
14226 2x2x0,60 5,1 45
14426 4x2x0,60 6,9 70
14626 6x2x0,60 8,2 85
14826 8x2x0,60 8,5 100
141026 10x2x0,60 8,9 120
142026 20x2x0,60 12,8 210
143026 30x2x0,60 13,8 300
144026 40x2x0,60 15,4 375
145026 50x2x0,60 17,1 445
146026 60x2x0,60 18,9 525
148026 80x2x0,60 21,8 710
1410026 100x2x0,60 24,2 870
Standard VDE 0815

Conductor resistance (loop)

0,60 mm = 130 Ω/km

Characteristic impedance

4~16 MHz : 100 +- 15 Ω

Insulation resistance

>5000 MΩ.km

Mutual Capacitance

Max. 52 nF/km

Capacity Unbalanced

Max. 400 pF / 300 mt

Operating voltage, peak Max 250 V
Test Voltage

Core / core : 1000 V

Core / Screen : 2000 V

Temperature range

Fixed: - 30 ºC ~ + 70 ºC

Mobile : -30ºC to +50ºC
Min. bending radius 10XD
Flame test

IEC 60332-3 & TS/DIN EN 50266-2-4

Smoke density test

IEC 61034-2 & TS/DIN EN 61034-2

Halogen-free properties test

IEC60754-1/2 & TS/DIN EN 50267-2

 

Conductor: Cu, class 1 (0.6mm). acc to  IEC 60228 / DIN VDE 0295
Insulation: Solid Polyethylene Compound (EN 50290-2-23)
Lay Up:

Pair twisted cores, up to 20 pair twisted in layers and fixed with PES tape.

Screen :

AL-PES tape with together (0,40 and/or 0,50 mm) mono tinned copper drain wire with screened.

Sheath:  halogen-free flame retardant polyolefin bond, ST8 acc. to IEC 60502-1
sheath color: Red (Ral3000)

These halogen-free cables are connection for computer peripheries, visual display units and printers. Transmission of datas up to 16 Mbit/s, suitable for ISDN applications. The use of installation cables for power cable applications or for underground installation is not permitted. These cables are used at schools, airpots, hospitals, etc. and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low.