PHONE : 982144972925-7+

H05VVH6-FH07VVH6-F

 H05VVH6-F/H07VVH6-F/Flat PVC Cables 
Packing* Cable weight External Dimensions Sheat thickness at broad flat part Insulation thickness Construction of individual conductor  number of cores x conductor cross-section .Code No
  .approx Nom nominal nominal nominal    
  kg/km mm mm mm nx mm N * mm²  
0.75mm2
CUT 90 4.1X12.2 0.9 0.6 24x 0.195 4G 0.75 51475
CUT 130 4.1X16.5 0.9 0.6 24x 0.195 5G 0.75 51575
CUT 160 4.1X 17.8 0.9 0.6 24x 0.195 6G 0.75 51675
CUT 230 4.1X 24.8 0.9 0.6 24x 0.195 9G 0.75 51975
CUT 300 4.1X 31.7 0.9 0.6 24x 0.195 12G 0.75 511275
CUT 400 4.1X 40.9 0.9 0.6 24x 0.195 16G 0.75 511675
CUT 450 4.1X 47.5 0.9 0.6 24x 0.195 18G 0.75 511875
CUT 510 4.1X 50.2 0.9 0.6 24x 0.195 20G 0.75 512075
CUT 555 4.1X 59.4 0.9 0.6 24x 0.195 24G 0.75 512475
1mm2
CUT 100 4.3X 12.9 0.9 0.6 31x 0.195 4G 1.0 51410
CUT 150 4.3X 17.4 0.9 0.6 31x 0.195 5G 1.0 51510
CUT 180 4.3X 18.9 0.9 0.6 31x 0.195 6G 1.0 51610
CUT 265 4.3X 26.3 0.9 0.6 31x 0.195 9G 1.0 51910
CUT 350 4.3X 33.7 0.9 0.6 31x 0.195 12G 1.0 511210
CUT 460 4.3X 43.7 0.9 0.6 31x 0.195 16G 1.0 511610
CUT 520 4.3X 50.6 0.9 0.6 31x 0.195 18G 1.0 511810
CUT 575 4.3X 53.6 0.9 0.6 31x 0.195 20G 1.0 512010
CUT 690 4.3X 63.5 0.9 0.6 31x 0.195 24G 1.0 512410
1.5mm2
CUT 140 5x 14.8 1 0.7 31x 0.230 4G 1.5 51415
CUT 200 5x 19.8 1 0.7 31x 0.230 5G 1.5 51515
CUT 240 5x 21.7 1 0.7 31x 0.230 6G 1.5 51615
CUT 350 5x 30.6 1 0.7 31x 0.230 9G 1.5 51915
CUT 465 5x 39.5 1 0.7 31x 0.230 12G 1.5 511215
CUT 620 5x 51.3 1 0.7 31x 0.230 16G 1.5 511615
CUT 700 5x 59.2 1 0.7 31x 0.230 18G 1.5 511815
CUT 770 5x 63.1 1 0.7 31x 0.230 20G 1.5 512015
CUT 910 5x 75.1 1 0.7 31x 0.230 24G 1.5 512415
2.5mm2
CUT 210 5.6x 18.0 1 0.8 51x 0.230 4G 2.5 51425
CUT 300 5.6x 24.6 1 0.8 51x 0.230 5G 2.5 51525
CUT 360 5.6x 26.8 1 0.8 51x 0.230 6G 2.5 51725
CUT 530 5.6x 37.6 1 0.8 51x 0.230 9G 2.5 51925
CUT 700 5.6x 48.4 1 0.8 51x 0.230 12G 2.5 511225
CUT 930 5.6x 62.9 1 0.8 51x 0.230 16G 2.5 511625
CUT 1050 5.6x 73.1 1 0.8 51x 0.230 18G 2.5 511825
CUT 1160 5.6x 77.3 1 0.8 51x 0.230 20G 2.5 512025
CUT 1390 5.6x 91.7 1 0.8 51x 0.230 24G 2.5 512425
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length`
Temperature during application: -5 °C up to +70 °C
fixed install Temperature: -30 °C up to +70 °C
Nominal voltage: Uο/U = 450/750 V
Test voltage: 2500 V
Maximal tensile strength: Static :15N/mm2   ------Dynamic :30 N/mm2
Conveyor speed: up to 120 m/min
Other characteristics: increased oil resistance; resistant to acids, alkali, UV-irradiation, moisture and ozone
Behaviour in fire: IEC 60332-1
Min. inner bending radius: 8D
Conductor: bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: PVC compound TI2 acc. to HD 21.1 / DIN VDE 0281 part 1 (YI2 acc. to VDE 0207 part 4)
Sheath: PVC compound TM2 acc. to HD 21.1 / DIN VDE 0281 part 1 (YM2 acc. to VDE 0207 part 5)
sheath color: Grey (Ral 7046)

Cable designed for inner and outdoor application, resistant to oil, moisture, UV-irradiation etc. Specially designed for frequent and strong bending in one plane, with small bending radius, which gives him exceptional flexibility and enables a very good space utilization. Used as supply cable and signalling cable for medium mechanical loads in dry, damp and wet areas. Applied for connection of mobile parts of machines, conveyors and linearly shifted massive equipment segments, specially for cranes, elevators, floor assembly lines and similar.