PHONE : 982144972925-7+

A-2Y(ST)2Y

Code No. Dimensions - number of External diameter Sheath thickness Cable weight Packing*
    Approx. nominal approx.  
  N x mm² mm mm kg/km  
Conductor Size :0.4mm
22224 2 x 2 x 0,4 4.7 1,0 19 CUT
22424 4 x 2 x 0,4 5.2 1,0 27 CUT
22624 6 x 2 x 0,4 5.8 1,0 35 CUT
22824 8 x 2 x 0,4 6.2 1,0 42 CUT
221024 10 x 2 x 0,4 6.5 1,0 49 CUT
222024 20 x 2 x 0,4 9.1 1,4 95 CUT
223024 30 x 2 x 0,4 11 1,4 138 CUT
224024 40 x 2 x 0,4 12.2 1,4 175 CUT
225024 50 x 2 x 0,4 12.7 1,8 202 CUT
227024 70 x 2 x 0,4 16.1 1,8 302 CUT
2210024 100 x 2 x 0,4 17.4 1,8 390 CUT
2215024 150 x 2 x 0,4 21.2 1,8 580 CUT
2220024 200 x 2 x 0,4 24.9 2,0 769 CUT
Conductor Size :0.6mm
22226 2 x 2 x 0,6 5.8 1 30 CUT
22426 4 x 2 x 0,6 6.6 1 46 CUT
22626 6 x 2 x 0,6 7.4 1 62 CUT
22826 8 x 2 x 0,6 8.1 1 77 CUT
221026 10 x 2 x 0,6 8.6 1 92 CUT
222026 20 x 2 x 0,6 12 1.4 182 CUT
223026 30 x 2 x 0,6 14.4 0.6 264 CUT
224026 40 x 2 x 0,6 16.6 1.8 348 CUT
225026 50 x 2 x 0,6 18.8 1.8 433 CUT
227026 70 x 2 x 0,6 20.7 1.8 575 CUT
2210026 100 x 2 x 0,6 24.4 2 811 CUT
2215026 150 x 2 x 0,6 29 2 1173 CUT
2220026 200 x 2 x 0,6 33.1 2.2 1536 CUT
Conductor Size :0.8mm
22228 2 x 2 x 0,8 6.8 1 47 CUT
22428 4 x 2 x 0,8 7.7 1 73 CUT
22628 6 x 2 x 0,8 8.9 1 100 CUT
221028 10 x 2 x 0,8 11.1 1.4 163 CUT
222028 20 x 2 x 0,8 15.2 1.8 309 CUT
223028 30 x 2 x 0,8 17.8 1.8 436 CUT
224028 40 x 2 x 0,8 19.9 1.8 563 CUT
225028 50 x 2 x 0,8 22.2 1.9 706 CUT
227028 70 x 2 x 0,8 25.8 2 961 CUT
2210028 100 x 2 x 0,8 30.4 2.2 1360 CUT
Temperature range
During Installation 5°C up to +50°C
Fixed Installed -30°C up to +70°C
Storage Temperature 40°C
Mechanical And Electrical Specifications
Operationg Voltage 300V
Test Voltage core/core U eff. 1500 V
Bending Radius 10XD
Insulation Resistance Min 5000MΩXKm
Mutual Resistance Max 55 nF/km
Capacitance Umbalance

0.4=250PF

0.6=250PF

0.8=160PF
Flame Behavior Acc to IEC 60332-1
Cable Standard Generally as IEC 60708
Conductor Anealed Copper Class1 (0.4, 0.6, 0.8mm)
Insulation PE Acc to EN 50290
Insulation Color Code ACC to  IEC 60708
Seperator Polyester Tspe
Screen PS tape+ Al/PS Tape+ Drain Wire
Sheath PVC Compound
Sheath Color Black

These multi-element metallic cables are designed for the signal transmission in instrumentation, analogue and digital communication, and control applications in process plants such as those found in the petrochemical and power generation industries. This range of cables is particularly suitable for applications requiring the cable to withstand electromagnetic interference due to their protective screen. RE-2Y(st)2Y are suitable for both fixed and mobile installations. Their low values of signal attenuation and low mutual capacitance enable signal transmission over long distances.